Online Order – TRi Shopping Cart

The Embedded PLC OEM Specialist Distributors Forum Try i-TRiLOGI +1-877-874-7527

Products  ›  Wx100 Series  ›  Wx-TERM16

Wx-TERM16 — Wx-TERM16 enclosed I/O terminal board mounted on DIN rail

Wx100 peripheral · Terminal board

Wx-TERM16

An enclosed I/O terminal board for the Wx100 with 16 digital inputs, 14 digital outputs, six configurable analog inputs and four independent analog outputs — plus an expansion port for the Wx-M1616.

16 DI / 14 DO 6 Analog In 4 Analog Out Expansion port Enclosed For Wx100
  • Inputs wire as PNP or NPN — tie the pullup terminal to V+
  • Four independent analog outputs: 2 × 0–5V and 2 × 0–20mA
  • Expansion port cascades Wx-M1616 boards to 80 in / 80 out
  • Pluggable screw terminals in an enclosed housing

Overview

More I/O, and room to grow.

The Wx-TERM16 is an enclosed I/O terminal board specifically designed for the Wx100 PLC. It provides connection for up to 16 digital inputs and 14 digital outputs. The inputs can be wired as PNP or NPN, up to 6 can be software configured as 0.5–5V analog inputs, and there are 4 independent analog outputs — two 0–5V and two 0–20mA.

Unlike the Wx-TERM8, it carries an expansion port. Cascading Wx-M1616 boards from it takes the system to 80 inputs and 80 outputs.

Features & benefits

High-end capability, standard.

Communication

  • Ribbon-cable connection to the Wx100
  • Expansion port for Wx-M1616 boards

I/O

  • 16 NPN/PNP selectable digital inputs
  • 14 NPN digital outputs, 2A continuous
  • 6 analog inputs, shared with DI 1–6
  • 4 analog outputs — 2 × 0–5V, 2 × 0–20mA
  • Expandable to 80 in / 80 out via Wx-M1616

Advanced

  • Enclosed housing
  • Pluggable screw terminals
  • DIN-rail mountable
  • Shares the Wx100's 12–24V DC supply

Specification

Full technical specification.

I/O
Digital Inputs (DI) 16 — NPN and PNP selectable / 12–24V DC
Digital Outputs (DO) 14 — NPN / 12–24V DC / 2A continuous
Analog Inputs (AI) 6 — single-ended 0.5–5V / 12-bit, shared with the first 6 DI
Analog Outputs (AO) 4 — single-ended 12-bit · 2 ch 0–5V · 2 ch 0–20mA
Expansion Port 1 — connects to Wx-M1616; cascade for up to 80 in / 80 out
Power
Board Supply 12–24V DC — share the PLC's supply, or common the grounds of separate supplies
Physical
Dimensions 5.20″(L) × 2.80″(W) × 1.42″(H) · 132 × 71 × 36 mm
Weight 6.3 oz (180 g)
Wiring Pluggable screw terminals
Environment
Operating Temperature −20 to +80 °C (−4 to +176 °F)
Operating Humidity 10%–90% RH, non-condensing
Vibration IEC 68-2-6/1980 · 1.6mm, 25–100Hz
Electrical Noise IEC801-4 fast transient · 2KV supply / 1KV I/O

Specifications sourced from the current triplc.com Wx-TERM16 datasheet — client to confirm before publication.

Compatible peripherals

Build out the Wx-TERM16.

Works with

Wx100 PLC

Expansion

Wx-M1616 (+32 I/O)

See all peripherals & accessories

Programming

Programmed through the Wx100.

The terminal board carries no firmware of its own — you program the Wx100 it connects to, using the same Ladder + TBASIC toolchain and free simulator.